SCT capture control register
CAPCONn_L | If bit m is one, event m causes the CAPn_L (UNIFY = 0) or the CAPn (UNIFY = 1) register to be loaded (event 0 = bit 0, event 1 = bit 1, etc.). The number of bits = number of match/captures in this SCT. |
CAPCONn_H | If bit m is one, event m causes the CAPn_H (UNIFY = 0) register to be loaded (event 0 = bit 16, event 1 = bit 17, etc.). The number of bits = number of match/captures in this SCT. |